Home > Products> Elevator Escalator Energy Saving> Elevator Energy Saving unit power saver
Elevator Energy Saving unit power saver
Elevator Energy Saving unit power saver

PFE

Brief Introduction:

PFE elevator energy saving Device is applicated for elevator, collect the renewable energy from the elevator operation, and return to the power grid and recycle,save up to 20-45% energy.


PFE elevator energy saving Device do not change the elevator original control system, as additional accessories to double ensure elevator operate safely and save energy.


PFE elevator energy saving Device is widely tested and approved by national elevator Quality testing center,Guangdong Special equipment testing center and so on, CE approved.

For more information you can click below link:

http://v.youku.com/v_show/id_XMTMzNjcxNTkxMg==.html?from=y1.7-1.2


Application:

Any elevator application field.



Products advantage:

LCL filtering : THD less than 5%


Flexible PWM: Perfect Output Wave

Patented Technology: Compatible with different brand elevator like OTIS,Hitachi,                                 Mitsubishi,Kone,Schindler,Fuji,Pllar,Sigma,Stannah,Toshiba,Thyssen,Thyssenkrupp and so on.

Smart software detecting: Save more energy than the old hardware control device


Item and specification:

Item

AC

V

Power

KW

CurrentA

Operate

VDC

Cable CrossMm2

Rated

Peak

Operate Wire

Control Wire

BPFE-02-011NDC

220

11

15

29

340

2.5

1.5

BPFE-02-018NDC

220

18.5

24

47

4

1.5

BPFE-02-022NDC

220

22

39

58

6

1.5

BPFE-02-030NDC

220

30

44

79

10

1.5

BPFE-02-037NDC

220

37

49

97

10

1.5

BPFE-02-045NDC

220

45

55

110

10

1.5

BPFE-04-011NDC

380

11

8

16

600

2.5

1.5

BPFE-04-018NDC

380

18.5

14

27

2.5

1.5

BPFE-04-022NDC

380

22

17

33

4

1.5

BPFE-04-030NDC

380

30

23

45

4

1.5

BPFE-04-037NDC

380

37

28

55

6

1.5

BPFE-04-045NDC

380

45

34

68

6

1.5


Please click here to have more information about the elevator energy saving device,including the principle and customer reference


IPC Elevator Energy saving unit Installation reference



Brand

Floors

Elevator Power(Kw)

Elevator Speed(M/S)

Saving Rate(%)

OTIS

30

27

2.5

31--36

OTIS

7

6

1

25--31

OTIS

33

30

1.75

17--20

OTIS

30

27

2.5

31-36

Mitsubishi

31

15

1.75

34--44

Mitsubishi

16

13

1.75

21--24

Mitsubishi

33

11.7

1.75

17--30

Mitsubishi

26

9.6

1.75

26--38

Kone

19

13.3

2

31--33

Kone

33

9

1.75

25--30

Kone

33

17.7

2.5

29--31

Kone

22

17.7

2

28--35

Kone

26

9

1.75

32--38

Kone

30

17.7

2.5

31--33

Kone

19

13.3

2

31--34

Kone

21

13.5

2

33--34

Sigma

18

11

1.75

29--31

Fuji

18

14.7

1.75

35--36

Fujitc

27

15

1.75

22--33

Toshiba

16

13

1.75

33--35

Hitachi

28

9.7

2.5

47--49

Hitachi

28

15

1.75

17.1-19.6

Hitachi

22

30

2

36-37.8

Hitachi

30

30

2.5

31--33

Hitachi

22

30

2

35--38

Hitachi

17

11.7

1.75

26--28

Hitachi

21

26

2.5

31--33

Hitachi

26

15

1

30--31




E-mail: sales@elevatorenergysaving.com

www.elevatorenergysaving.com

PFE Elevator energy saving unit used in OTIS elevator

1.This article introduced the PFE elevator energy saving unit used in OTIS elevator, on site operation shows that the regenerated energy by PFE can be returned to power grid and recycle, and elevator energy saving is Feasible.

Key Word: PFE elevator energy saving      OTIS elevator     Energy feedback


2. OTIS (300VFE) Specification:

Speed:2.5m/s

Floors: 30 Floors

Load:1000Kg

Motor Power: 27KW

Rated Current:49A

Rated Voltage: 380V

Operation Specification:

VFD Input Current:56A

VFD Input Voltage: 387V

Braking Resistor constant output current:10A

Braking Resistor constant output voltage: 50V

Braking Resistor braking current:35A

Braking Resistor braking voltage: 150V

VFD PN site DC voltage(V)

Elevator Stop: 540V

Elevator Going UP: 612V

Elevator Going Down: 532V


3.Elevator energy consumption problem

Elevator which use VFD when reach the max speed, when approaching the appointed floor, need to slow down and stop, in this process, Traction Machine will need to release the energy.

Elevator also have the potential energy, there is a balance load which is around 50% of elevator full load weight(One Ton elevator around 7 people weight), only in this situation elevator balance load equal the elevator car with  Passengers.In other case, the elevator is unbanalced, so will have extra potential energy, when elevator car is lighter than balanced load, elevator regenerated energy when going up, and consume energy when going down, and when elevator car is heavier than balanced load, will consume energy when going up, and regenerated energy when going down.

When these extra energy returned to VFD, it will cause the DC voltage rising, to protect VFD, usually there will have a braking unit to consume these energy, this is not only waste the energy, but also making the operation room temperature rising fast, and reduce all the equipment life, so usually need air conditioner to cool the operation room.

If we collect these braking energy and convert to AC power to be used for some other equipment, then not only save these energy but also reduce the heat release from braking resistor, and even no need to use air conditioner, extend the equipment life and save energy.


4. Energy saving Solution

Item

Specification

Item

Specification

VFD

HLF-37C

Rated Power

37KW

Rated Voltage

380V

Rated Current

28A

Peak Current(A)

55A

Quantity

1 unit

(1). Connection Diagram

2Connection with VFD





Elevator energy saving DC(+) DC(-) Connect toVFDDC(+) DC(-).

5. Elevator Energy saving Data collection

Date

Time

Main Meter Data

Saving Meter Data

Saving Rate

Record

Kwh Used

Record

Kwh Used

2012.03.19

10:00

0.5

0

2012.03.20

10:00

49.2

48.7

17.2

17.2

26.1%

2012.03.21

10:00

95.3

46.1

34.0

16.8

26.7%

2012.03.22

10:00

142.8

47.5

51.8

17.8

27.25%

2012.03.23

10:00

188.0

45.2

68.1

16.3

26.37%

2012.03.24

10:00

230.8

42.8

83.9

15.8

26.96%

2012.03.25

10:00

266.5

35.7

98.0

14.1

28.31%

2012.03.26

10:00

295.9

29.4

108.2

10.2

25.75%

108.2

26.87%

Note: Cause the Mechanical meter can run reverse when energy is regenerated, so need to add the saving meter record.



6.Elevator energy saving Benefit

From the data collection we can have the following result:

Elevator energy consumption Per week

295.4 Kwh

Energy Saving per week

108.2 Kwh

Average saving rate

26.87%

Energy Saving Per Year

108.2x52.14=5641.54 Kwh

Money Saving Per Year

5641.54x$0.15/Kwh=$846.23

Note: electricity cost $0.15/Kwh, and 52.14 week per year.

So we can see that one elevator energy saving unit will save up to 108.2KWH, and each year save $846.23, and also will reduce the air conditioner cost and energy saving in the operation room , since temperature reduce will ensure the equipment in operation room have much longer life.